Don gloves by gripping the cuff to avoid contamination.
Grab the cuff.
Remove the glove so it turns inside out.
Insert your free hand under the cuff of the other glove.
Remove the glove so it turns inside out.
Dispose of in a proper waste basket.
Clean all articles, surfaces, and equipment before applying.
Spray or wipe Alsoft Alpet D2 on the surface until thoroughly wet.
Allow disinfectant to dwell on the surface for 60 seconds.
Apply an appropriate amount into your hands, wash thoroughly, rinse well under running water, and dry completely.
Place hands under the sensor to active and dispense a premeasured amount of hand hygiene solution.
Rinsing Water: Dilute 3ml of the amino lotion in 2 L of hot water and apply after the bath, wiping the excess water with a clean dry towel. No need to rinse.Bed Bath: Dilute 3ml of the amino lotion in 2 L of hot water. Soak a towel in the...
Step on the pedal to activate the dispenser.
Step on the pedal to activate the dispenser.
Wet the sponge brush with water and squeeze excess. Remove the soil by rolling the sponge brush in the mouth. Apply a moisturizing agent to the brush if needed.
Jet Cleaning
Pump a dilution into a jet washer.
The recommended concentration for use is 0.5% (50mL/10L of water).
Adjust between 0.2% and 0.5% (20 to 50mL/10L of water) according to the degree of soil.
Put the used instruments in the jet...
Ultrasonic Cleaning
Prepare a dilution with water in an ultrasonic washer basin.
The recommended concentration for use is 1.0% (100mL/10L of water).
Adjust between 0.5% and 2.0% (50 to 200mL/10L of water) depending on the degree of soil.
Put...
Ultrasonic Cleaning
Prepare a dilution with water in an ultrasonic washer basin.
The recommended concentration for use is 1.0% (100mL/10L of water).
Put the used instruments into the basin, then wash for 10 to 15 minutes according to the...
Ultrasonic Cleaning
Prepare a dilution with water in an ultrasonic washer basin.
The recommended concentration for use is 0.5% (50mL/10L of water).
Adjust between 0.2% and 0.5% (20 to 50mL/10L of water) depending on the degree of soil.
Put...
Manual (Immersion) Cleaning
Prepare a 1% dilution with warm water (around 40°C).
The recommended concentration for use is 1.0% (100mL/10L of water).
Adjust between 0.5% and 2.0% (50 to 200mL/10L of water) depending on the degree of soil.
Immerse...
Apply undiluted solution to a wet sponge.
Work up a lather and wash instruments by hand.
Rinse completely with running water.
Prepare a dilution with warm water (around 40°C).
The recommended concentration for use is 1.0% (100mL/10L of water).
Adjust between 0.5% and 2.0% (50 to 200 mL / 10L of water) depending on the degree of soil.
Immerse the used medical instruments...
Manual Cleaning
Prepare a dilution with warm water (around 40°C).
The recommended concentration for use is 1.0% (100mL/10L of water).
Adjust between 0.5% and 2.0% (50 to 200mL/10L of water) depending on the degree of soil.
Immerse the used...
Prepare a dilution in a covered container.
The recommended concentration for use is 5.0% (200mL/4L of water).
Immerse the medical instruments with heat stains in the dilution for 5 minutes.
Drain the instruments well and rinse thoroughly...
Manual Cleaning
Prepare a dilution with warm water (around 40°C).
The recommended concentration for use is 1.0% (100mL/10L of water).
Adjust between 0.5% and 1.0% (50 to 100mL/10L of water) depending on the degree of soil.
Immerse the used...
Manual Cleaning
Prepare a dilution with warm water (around 40°C).
Recommended concentration for use is 1.0% (100mL/10L of water).
Adjust between 0.5% and 2.0% (50 to 200mL/10L of water) depending on the degree of soil.
Immerse the used...